Version 3.5.1.19
(1) The ASSA gateway for WiFi/POE products is not yet Windows 8 or Windows Server 2012 compatible. The software installer will not allow the ASSA gateway to be installed if the operating system is either Windows 8 or Windows Server 2012.
Note: Doors.Net software IS NOT compatible with any Home/Basic version of Windows XP, Windows Vista, Windows 7, or Windows 8.
This is due to networking restrictions built into the Home/Basic versions of Windows operating systems.
New Features
New Hardware Release:
- The GIOX (Greater I/O Board) has been released for use by NXT and Mercury Powered NXT controllers. The GIOX unit is made up of a back plane and a combination of Input and/or Output plug-in modules. The back plane handles up to 8 plug-in modules in any combination of input module or output module. Input modules have 8 inputs and Output modules have 8 outputs. This product can be used for either Elevator Control or general I/O; the two uses cannot be mixed in one GIOX unit. Elevator Control is currently only supported on Mercury Powered NXT controllers.
For All Hardware Platforms:
- Doors.NET is now capable of running multiple concurrent hardware gateways. In a multiple concurrent gateway system, the software limits itself to the lowest hardware common denominator for certain operating parameters. Also, certain features may be displayed, but may only apply to one specific gateway, and not to any other gateways. The factory default allows one gateway. There are additional charges for each additional gateway and your license must be updated to enable each additional gateway. This includes any combination of the following gateways:
- NXT
- Mercury Powered NXT
- PXL-500 Series
- Standard Mercury
- ASSA Aperio and WiFi/POE
- Ingersoll-Rand/Schlage
-
Unique to Keri NXT Controllers:
Unique to Keri PXL Controllers:
Unique to Keri NXT Mercury Powered Controllers and Mercury Hardware:
Unique to ASSA Aperio Lock Hardware:
Unique to ASSA WiFi/POE Lock Hardware:
Unique to IR/Schlage Lock Hardware:
Program Improvements
For All Hardware Platforms:
- Corrected an issue that prevented the Auto Config window from closing if the installer opted not to complete the Auto Config process.
- Added the ability to clear the Roll Call list at a specific time every day.
- Corrected an issue that would not allow a remote client delete a photo in a cardholder record.
- Corrected an issue with activating Host Schedule triggers in global linkages and when using the System Calendar.
- Changed manual entry of MAC addresses to no longer be case-sensitive.
- Changed the time stamp used for event reports from the server time stamp to the controller time stamp. The controller time stamp reflects the time the event occurred, and is typically the information that these types of reports are presenting.
- When setting the ADA/DDA option for a cardholder, enabling either the Extended (ADA/DDA) value for the Cardholder Type or the Use ADA/DDA Timing check box also enables the other setting. You can then disable one value or the other if desired.
- When performing a client-only installation the software will now not automatically run the license manager as this step is unnecessary.
Unique to NXT Controllers:
- Set a limit to the number of times the software reports a controller is offline. Previously the software would report "controller offline" every time an attempt was made to reconnect. Now it will only report the offline condition the first time it occurs. The report enables itself once the controller comes back online.
- Corrected a gateway issue with the holiday index running out of space causing doors to not unlock on a holiday when Active on Holiday is set.
- Added checks to ensure Holiday schedules and associated limits are being applied correctly.
Unique to PXL Controllers:
- Made a number of gateway improvements to accommodate network timing conditions in medium to large controller networks (typically 20 controllers or more).
- Corrected an issue with single-door applications using two readers. Operating parameters assigned to the second reader are now properly applied to that reader.
- Implemented a check to prevent multiple back-to-back Update Network requests from being executed.
- Corrected an issue where if a Secondary controller was reset and then comes back online, the property grid was correctly updated, but the status grid was not until a request status command is performed. The status grid now does a real-time update to ensure displayed information is correct.
- Made a number of improvements to the reporting function options.
- Added checks to ensure Holiday schedules and associated limits are being applied correctly.
Unique to Keri NXT Mercury Powered Controllers and Mercury Hardware:
- Added support for a double credential presentation feature allowing a double-presentation of a credential be a local linkage trigger.
- Corrected an issue with temporary cards disabling themselves 1 minute late.
- Added credential Use Count to the credential template.
- Corrected the clock synchronization feature in the System Calendar. It was not properly synchronizing the controllers with the host computer. Also added the ability to synchronize all controller clocks at one time.
- Added a new Reader mode control "timed to action list" option to Local Linkages. Allows a local linkage macro to set any Reader mode for a designated amount of time.
- Added support for IPv6 addressing.
Unique to ASSA Aperio Hardware:
- Added support for new devices - Securitron R100, HES KS100, and AS100.
- Added a Scheduled Relock command.
- Added support for the Situation Manager feature.
- Corrected an issue with event display filtering.
- Added a Scheduled Relock command.
Unique to ASSA WiFi/POE Hardware:
- Added support for remote Unlock/Lock. These lock sets must have the Always Connect option enabled.
- Added support for the Situation Manager feature.
- Corrected an issue with event display filtering.
- Implemented new WiFi/POE drivers provided by ASSA. Driver version is now 4.4.
Note: If you are upgrading an existing ASSA WiFi/POE installation you must manually remove the existing ASSA driver (version 1.2) before running the Doors.NET installer.
Unique to IR/Schlage Hardware:
- Corrected the display of the Interior Push Button indicator.
- Corrected temp LED commands.
- Corrected operation in Card OR PIN mode.
- Now actively requesting Wake-on-Radio status, improving notification of latch state changes.
- Corrected a backwards compatibility issue for operation with older AD-series locksets.
Known Issues
With NXT Controllers:
- If additional doors are added to an existing access group, causing a cardholder in that access group to exceed eight access levels, then Update Network will not work for that controller. To correct this condition the operator will have to review access group/door assignments and determine which assignment exceeds the limit. This will be corrected in the next software release.
With PXL Controllers:
- PXL controllers, by default, are configured for a standard credential file size. Features such as Temp Cards, Anti Passback, Card + PIN, require a extended credential file size. Under most situations, the PXL gateway automatically notifies controllers on the line that a switch to extended credential file size is required. This is not being done correctly when Temp Cards is the feature being activated. The workaround is to manually perform a full update to the controllers. This will be corrected in the next software release.
Firmware Requirements
For NXT controllers and peripherals:
- Standard NXT controllers require new firmware revision 2.05.40.
- NXT Readers require firmware revision 3.00.01 or greater.
- Reader Interface Modules (RIMs) require firmware revision 3.02.05 or greater.
- 4x4 I/O Modules require firmware revision 3.00.02.
For PXL:
- PXL controllers require firmware revision 8.6.09.
- Legacy PXL controllers should be at firmware revision 8.4.49 or greater (this firmware revision is programmed with the current U.S. Daylight Savings Time dates and has the complete PXL implementation of Anti-Passback).
For Mercury Powered NXT controllers and Mercury Hardware:
- Mercury Powered NXT controllers require new firmware revision 1.185.
Firmware Upgrades
NXT Firmware v2.05.40
- Added support for updating NXT Reader firmware.
- Implemented a number of Ethernet communication enhancements that help protect the controller from data that does not apply to the controller, including bad data packets and invalid connection attempts. These changes help to prevent the controller from being knocked offline.
- Added a health monitor to collect and save information on questionable Ethernet events. This information can be used to assist in debugging Ethernet related issues. This feature is selectively enabled, and should only be used if a controller has repeated networking issues.
- Corrected an error in applying holiday dates to door unlock schedules.
Mercury Hardware Firmware v1.185
- The 4x4 status command now provides more status information.
- Corrected the red LED display pattern when in 2-wire LED control mode.
- Corrected a configuration issue with Schlage AD300 lock sets that could cause the controller to reset.
- Now actively requests Schlage Wake-on-Radio status, improving the reporting of latch state changes.
- Corrected Schlage lock set operation in Card OR PIN mode.
- Added extended lock set modes: Classroom, Office, Privacy, and Apartment/Canadian-Law.
- Double card presentation is treated as a toggle state in extended lock set modes Classroom and Office.
- Added support for OSDP biometric types.
-
IPv6 web connections now use Zeroconf name, resolving browser incompatibilities with IPv6 literal addresses.
-
Made changes to how Scheduled Override for Aperio operates when invoked by a linkage trigger to accommodate the triggering condition. This prevents conflicting operations from occurring.
-
Corrected a backwards compatibility issue with older Schlage AD-series locksets.
Translations
Completed Translations:
- Chinese (Simplified)
- Chinese (Traditional/Taiwan)
- English (UK)
- French (France)
- Polish
- Russian
- Slovenian
- Spanish (Castilian)
- Turkish
Translations Pending Updates *:
- Arabic (UAE)
- Dutch (Belgium)
- French (Belgium)
- Italian